Document details

Planar LAAPDs: temperature dependence, performance, and application in low-ener...

Author(s): Ludhova, L. cv logo 1 ; Amaro, F. D. cv logo 2 ; Antognini, A. cv logo 3 ; Biraben, F. cv logo 4 ; Cardoso, J. M. R. cv logo 5 ; Conde, C. A. N. cv logo 6 ; Covita, D. S. cv logo 7 ; Dax, A. cv logo 8 ; Dhawan, S. cv logo 9 ; Fernandes, L. M. P. cv logo 10 ; Hänsch, T. W. cv logo 11 ; Hughes, V.-W. cv logo 12 ; Huot, O. cv logo 13 ; Indelicato, P. cv logo 14 ; Julien, L. cv logo 15 ; Knowles, P. E. cv logo 16 ; Kottmann, F. cv logo 17 ; Lopes, J. A. M. cv logo 18 ; Liu, Y.-W. cv logo 19 ; Monteiro, C. M. B. cv logo 20 ; Mulhauser, F. cv logo 21 ; Nez, F. cv logo 22 ; Pohl, R. cv logo 23 ; Rabinowitz, P. cv logo 24 ; Santos, J. M. F. dos cv logo 25 ; Schaller, L. A. cv logo 26 ; Taqqu, D. cv logo 27 ; Veloso, J. F. C. A. cv logo 28

Date: 2005

Persistent ID: http://hdl.handle.net/10316/4425

Origin: Estudo Geral - Universidade de Coimbra

Subject(s): Low-energy X-ray spectroscopy; Large Area Avalanche Photodiodes performance; Temperature dependence; Response to [alpha] particles


Description
An experiment measuring the 2S Lamb shift in muonic hydrogen ([mu]-p) was performed at the Paul Scherrer Institute, Switzerland. It required small and compact detectors for 1.9 keV X-rays (2P-1S transition) with an energy resolution around 25% at 2 keV, a time resolution better than 100 ns, a large solid angle coverage, and insensitivity to a 5 T magnetic field. We chose Large Area Avalanche Photodiodes (LAAPDs) from Radiation Monitoring Devices as X-ray detectors, and they were used during the last data taking period in 2003. For X-ray spectroscopy applications, these LAAPDs have to be cooled in order to suppress the dark current noise; hence, a series of tests were performed to choose the optimal operation temperature. Specifically, the temperature dependence of gain, energy resolution, dark current, excess noise factor, and detector response linearity was studied. Finally, details of the LAAPDs application in the muonic hydrogen experiment as well as their response to [alpha] particles are presented. http://www.sciencedirect.com/science/article/B6TJM-4F1S98H-4/1/06125e040d69c985c7b62cfe58fd372b
Document Type Article
Language English
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Related documents



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento EU