The double cantilever beam test applied to mode I fracture characterization of ...

Author(s): Morais, J.J.L. cv logo 1 ; Moura, M.F.S.F. cv logo 2 ; Pereira, F.A.M. cv logo 3 ; Xavier, J. cv logo 4 ; Dourado, N. cv logo 5 ; Dias, Maria Isabel R. cv logo 6 ; Azevedo, Jorge Manuel Teixeira de cv logo 7

Date: 2010

Persistent ID: http://hdl.handle.net/10348/1742

Origin: Repositório da UTAD

Subject(s): Bone; Compliance; Fracture toughness; modeling


Description
the primary objective of this work was to analyse the adequacy of the Double Cantilever Beam(DCB) test in determining fracture toughness under pure mode I loading of cortical bone tissue.A new data reduction scheme based on specimen compliance and the crack equivalent concept was used to overcome the difficulties inherent in crack monitoring during its growth. It provides a complete resistance curve, wich is fundamental in estimating the fracture energy. A cohesive zone model was used to simulate damage initiation and prpagation, thus assessing the efficacy of the proposed testing method and data reduction scheme. Subsequently, the DCB test was applied to evaluate the mode I fracture energy of hidrated and termally dehydrated cortical bone tissue from young bovine femur , in the tangential-longitudinal prpagation system. The results obtained demonstrate the efficaacy of the DCB test and the proposed data reduction scheme on the bone fracture characterization onder mode I loading.
Document Type Article
Language English
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Related documents



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento EU