Autor(es):
Lima, Joana
; Teixeira, P.
; Azeredo, Joana
; Oliveira, Rosário
Data: 2004
Identificador Persistente: http://hdl.handle.net/1822/3610
Origem: RepositóriUM - Universidade do Minho
Descrição
The retention of bacteria on food processing surfaces increases the risk of
cross-contamination of these microorganisms in food. Listeria monocytogenes is a
foodborne pathogen of significant concern in the food industry. This bacteria
occurs widely in the environment and has been isolated from a range of
sources including vegetables, processed foods, silage and soil (Cox et al., 1989).
It is well known that initial bacterial adhesion to a surface is determinant to
surface colonization. Surface properties as hydrophobicity, electrical charge,
roughness and porosity, are determinant in the adhesion process. The aim of
this study was to investigate the effect of hydrophobicity in the adhesion of
Listeria monocytogenes ATCC 15313 to stainless steel (SS) and to polypropylene
(PP), which are materials commonly used in domestic kitchens as well as in all
the food industry. Adhesion assays were conducted by incubating coupons of
the materials studied with a cellular suspension of 1.74x10 8cells/ml, for 2 hours
at 25 ºC. After washing, the coupons were stained with a 0.01% DAPI solution
and observed by epifluorescence microscopy. The adhered cells were counted
using an automate enumeration software. The hydrophobicity of bacteria and
materials was determined through contact angle measurements. Both materials
are hydrophobic, being stainless steel the most hydrophobic one. L.
monocytogenes is hydrophilic. Probably, this explains the higher adhesion of L.
monocytogenes to SS (3.63x10 6 cells/cm²) than to PP (2.7x10 5 cells/cm²). On the
basis of these results, optimisation of disinfection procedures or the use of
other materials in order to reduce adhesion is recommended.
Cox L.J., Kleiss, T., Cordier J.L. Food Microbiology, 6, 49-61, (1989).