Detalhes do Documento

Electrochemical behaviour of isatin at a glassy carbon electrode

Autor(es): Diculescu, Victor C. cv logo 1 ; Kumbhat, Sunita cv logo 2 ; Oliveira-Brett, Ana Maria cv logo 3

Data: 2006

Identificador Persistente: http://hdl.handle.net/10316/5076

Origem: Estudo Geral - Universidade de Coimbra

Assunto(s): Oxidation; Reduction; Voltammetry


Descrição
The electrochemical behavior of isatin - a molecule with a broad range of applications in synthetic, biological and clinical activity - has been investigated over a wide pH range at a glassy carbon electrode (GCE) using cyclic, square wave and differential pulse voltammetry. The oxidation of isatin is an irreversible process, pH dependent and occurs with the formation of a main oxidation product that strongly adsorbs on the electrode surface. The reduction of isatin is also a pH dependent irreversible process. Cyclic voltammograms show two consecutive charge transfer reactions. The diffusion coefficient of isatin was calculated in pH 7.0 phosphate buffer to be D0 = 4.9 × 10-7 cm2 s-1. The limit of detection obtained in a solution of pH 7.0 phosphate buffer was LOD = 0.194 [mu]M, based on three times the noise level. http://www.sciencedirect.com/science/article/B6TF4-4K3N5RG-4/1/99ab4825e838a8e8c4bf07df3629ae82
Tipo de Documento Artigo
Idioma Inglês
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Documentos Relacionados



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia