Encontrados 7 documentos, a visualizar página 1 de 1

Ordenado por Data

A large area timing RPC prototype for ion collisions in the HADES spectrometer

Alvarez Pol, H.; Alves, R.; Blanco, A.; Carolino, N.; Eschke, J.; Ferreira-Marques, R.; Fonte, P.; Garzón, J. A.; González Díaz, D.; Pereira, A.

We present a resistive plate chamber (RPC) prototype for time-of-flight measurements over large areas and at high occupancies, minimizing the inter-channel cross-talk. ; http://www.sciencedirect.com/science/article/B6TJM-4D75GPD-9/1/a6fe40c114a867a0f98e2fec0f133503


Performance of shielded timing RPCs in a 12C fragmentation experiment

Alvarez Pol, H.; Alves, R.; Blanco, A.; Carolino, N.; Eschke, J.; Ferreira-Marques, R.; Fonte, P.; Garzón, J. A.; González Díaz, D.; Pereira, A.

We show the feasibility of large area timing RPC detectors for experiments dealing with fragmentation-like primary interactions and/or high detector multiplicities, without significative degradation of the detector capabilities. The tested prototype is constituted by three independent cells placed into grounded aluminium boxes, which reduce the cross-talk to the level of 0.4%. Each box consists of a 4-gap glass...


Hadron energy reconstruction for the ATLAS calorimetry in the framework of the ...

Akhmadaliev, S.; Amaral, P.; Ambrosini, G.; Amorim, A.; Anderson, K.; Andrieux, M. L.; Aubert, B.; Augé, E.; Badaud, F.; Baisin, L.; Barreiro, F.

This paper discusses hadron energy reconstruction for the ATLAS barrel prototype combined calorimeter (consisting of a lead-liquid argon electromagnetic part and an iron-scintillator hadronic part) in the framework of the non-parametrical method. The non-parametrical method utilizes only the known e/h ratios and the electron calibration constants and does not require the determination of any parameters by a min...


Results from a new combined test of an electromagnetic liquid argon calorimeter...

Akhmadaliev, S.; Albiol, F.; Amaral, P.; Ambrosini, G.; Amorim, A.; Anderson, K.; Andrieux, M. L.; Aubert, B.; Augé, E.; Badaud, F.; Baisin, L.

A new combined test of an electromagnetic liquid argon accordion calorimeter and a hadronic scintillating-tile calorimeter was carried out at the CERN SPS. These devices are prototypes of the barrel calorimeter of the future ATLAS experiment at the LHC. The energy resolution of pions in the energy range from 10 to 300 GeV at an incident angle [theta] of about 12° is well described by the expression , where E is...


High-resolution RPCs for large TOF systems

Fonte, P.; Marques, R. Ferreira; Pinhão, J.; Carolino, N.; Policarpo, A.

Here, we report on a particular type of RPC that presents up to 99% efficiency for minimum ionizing particles and a very sharp time resolution, below 50 ps [sigma] in the most optimized conditions. Our 9 cm2 cells, made with glass and metal electrodes that form accurately spaced gaps of a few hundred micrometers, are operated at atmospheric pressure in non-flammable gases and can be economically produced in lar...


Hadronic shower development in Iron-Scintillator Tile Calorimetry

Amaral, P.; Amorim, A.; Anderson, K.; Barreira, G.; Benetta, R.; Berglund, S.; Biscarat, C.; Blanchot, G.; Blucher, E.; Bogush, A.; Bohm, C.; Boldea, V.

The lateral and longitudinal profiles of hadronic showers detected by a prototype of the ATLAS Iron-Scintillator Tile Hadron Calorimeter have been investigated. This calorimeter presents a unique longitudinal configuration of scintillator tiles. Using a fine-grained pion beam scan at 100 GeV, a detailed picture of transverse shower behaviour is obtained. The underlying radial energy densities for the four depth...


Evaluation of Fermi read-out of the Atlas Tilecal prototype

Ajaltouni, Z.; Albiol, F.; Alifanov, A.; Amaral, P.; Amelin, D.; Amorim, A.; Anderson, K.; Angelini, C.; Agnvall, S.; Antola, A.; Astesan, F.

Prototypes of the FERMI system have been used to read out a prototype of the ATLAS hadron calorimeter in a beam test at the CERN SPS. The FERMI read-out system, using a compressor and a sampling ADC, is compared to a standard charge integrating read-out by measuring the energy resolution of the calorimeter separately with the two systems on the same events. ; http://www.sciencedirect.com/science/article/B6TJ...


7 Resultados

Texto Pesquisado

Refinar resultados

Autor











Data





Tipo de Documento


Recurso


Assunto















    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia