A series of monotonic and cyclic tests on unstrengthened full-scale specimens were performed in order to characterize the original behavior of connections representative of traditional timber trusses. Subsequently, connections strengthened with metal devices were tested under monotonic and cyclic loading. Tests on assembled connections were preceded by accurate material characterization, in terms of the mechani...