In industrial practice, there is a demand for a reference standard for viscosity that is established for a readily available fluid to simplify the calibration of industrial viscometers for moderately high viscosities [(50 to 125) mPa · s]. Diisodecyl phthalate (DIDP) has been suggested as that reference fluid, and a number of studies of its properties have been carried out in several laboratories throughout the...
The refrigerant blend R-507A (50 wt % HFC-143a, 50 wt % HFC-125) is an azeotropic mixture of hydrofluorocarbon refrigerants, 1,1,1-trifluoroethane (HFC-143a) and pentafluoroethane (HFC-125). The paper reports viscosity measurements, performed with a vibrating-wire viscometer, of the refrigerant blend R-507A,at five temperatures in the range (253 to 293) K. The measurements were carried out at pressures from sli...
The present article describes a novel vibrating-wire viscometer that has been shown to be able to measure viscosities up to 135 mPaâs, after calibration against water at 20 °C, to provide direct traceability to the primary reference for viscosity. For the purpose of validating the instrument, measurements of the viscosity of some selected fluids, including standard reference liquids with viscosity on the order ...
A recently developed dual vibrating-wire technique has been used to perform viscosity measurements of liquid toluene in the temperature range 213 K ≤ T ≤ 298 K, and at pressures up to approximately 20 MPa. The results were obtained by operating the vibrating-wire sensor in both forced and free decay modes. The estimated precision of the viscosity measurements, in either mode of operation, is ±0.5%, for temperat...
This paper reports new measurements of the viscosity of R32 and R125, in both the liquid and the vapor phase, over the temperature range 220 to 343 K near the saturation line. The measurements in both liquid and vapor phases have been carried out with a vibrating-wire viscometer calibrated with respect to standard reference values of viscosity. It is estimated that the uncertainty of the present viscosity data ...
The paper reports new measurements of the viscosity of liquid R134a over the temperature range 235 to 343 K and pressures up to 50MPa. The measurements have been carried out in a vibrating-wire viscometer calibrated with respect to the viscosity of several liquid hydrocarbons. It is estimated that the uncertainty in the viscosity data reported is +0.6%. The data therefore have a lower uncertainty than that of e...
The design and operation of two independent vibrating-wire viscometers are described. The instruments are intended for operation in the liquid phase at pressures up to 300 MPa and have been designed specifically for this purpose using the detailed theory of the device. Extensive evidence is adduced to demonstrate that the operation of the viscometers is consistent with the theory. Although the instruments attai...
This paper presents a study of the influence of branching in the binary diffusion coefficients of n-heptane+n-hexane isomers, in the liquid state. The measurements have been made with the Taylor dispersion technique, at several compositions, at 283 and 298 K, for the X+n-heptane mixtures, where X=n-hexane, 3-methylpentane, 2, 3-dimethylbutane, and 2, 2-dimethylbutane. The results show a very interesting behavio...
A preliminary study of the effect of branching in the binary diffusion of hexane isomer + n-heptane systems is presented. Measurements have been performed with an instrument modeled for the Taylor dispersion technique, at several compositions, at 297 K, for the n-hexane + n-heptane and 2,2-dimethylbutane + n-heptane binary mixtures. The accuracy is estimated to be 1%. The influence of branching is discussed. It...