Encontrados 9 documentos, a visualizar página 1 de 1

Ordenado por Data

Comparison of visual and refractive results of Toric Implantable Collamer Lens ...

Alfonso, José F.; Fernández-Vega, Luis; Fernandes, Paulo Rodrigues; González-Méijome, José Manuel; Montés-Micó, Robert

PURPOSE: To compare visual and refractive results of Toric Implantable Collamer Lens (TICL) and bioptics (ICL plus excimer corneal surgery) to treat myopic astigmatism. METHODS: Eighty-one eyes underwent TICL implantation and 83 eyes were treated with bioptics (corneal ablation was performed between 1.5 and 6 months after ICL implantation). Uncorrected distance visual acuity (UDVA), corrected distance visual a...


Central vault after phakic intraocular lens implantation : correlation with ant...

Alfonso, José F.; Fernández-Vega, Luis; Lisa, Carlos; Fernandes, Paulo Rodrigues; Jorge, Jorge; Montés-Micó, Robert

To compare the central postoperative vault of a phakic intraocular lens (pIOL) to correct myopia, myopic astigmatism, and hyperopia and identify ocular and lens parameters that might predict the vault amount.


Implantable collamer posterior chamber intraocular lenses : a review of potenti...

Fernandes, Paulo Rodrigues; González-Méijome, José Manuel; Madrid-Costa, David; Ferrer-Blasco, Teresa; Jorge, Jorge; Montés-Micó, Robert

Artigo submetido ; PURPOSE: To review the peer-reviewed literature reporting pstoperative complications of the most recent models of Visian Implantable Collamer posterior chamber intraocular lenses (ICL, STAAR Surgical Co). METHODS: A literature search of the PubMed database was performed to identify all articles related to ICL complications. Articles were obtained and reviewed to identify those that reported ...


Posterior chamber collagen copolymer phakic intraocular lenses to correct myopi...

Alfonso, José F.; Baamonde, Begoña; Fernández-Vega, Luis; Fernandes, Paulo Rodrigues; González-Méijome, José Manuel; Montés-Micó, Robert

PURPOSE: To evaluate the long-term safety and efficacy of posterior chamber collagen copolymer phakic intraocular lens (pIOL) implantation to correct myopia. SETTING: Fern!andez-Vega Ophthalmological Institute, Oviedo, Spain. DESIGN: Cohort study. METHODS: Uncorrected (UDVA) and corrected (CDVA) distance visual acuities, refraction, pIOL vault, endothelial cell loss, and adverse events were evaluated for 5 year...


Prevalence of refractive conditions in the general population attending eye car...

Queirós, A.; Ferrer-Blasco, Teresa; Jorge, Jorge; Matos, Sofia Cláudia Peixoto de; González-Méijome, José Manuel; Cerviño, Alejandro

The purpose of this study was to report the fi rst estimations on the prevalence of refractive conditions in a Portuguese population attending several ophthalmologic and optometric clinics within the same region. Methods: Values of non-cycloplegic subjective refraction from the right eye of 4288 patients (40.08±18.75 years) were analyzed to estimate the prevalence of refractive conditions as a function of age a...


Age-related changes in the human visual system and prevalence of refractive con...

Ferrer-Blasco, Teresa; González-Méijome, José Manuel; Montés-Micó, Robert

PURPOSE: To retrospectively report the trends of change in several parameters of the human visualsystem over a wide age range in patients attending an eye clinic. SETTING: University of Valencia, Valencia, Spain. METHODS: The clinical records of 2654 patients were retrospectively reviewed, and the age, sex, spherocylindrical refraction, visual acuity, keratometry, and intraocular pressure were obtained. Descrip...


Effect of sport-tinted contact lenses for contrast enhancement on retinal stray...

Cerviño, Alejandro; González-Méijome, José Manuel; Linhares, João M. M.; Hosking, Sarah; Montés-Micó, Robert

PURPOSE: To investigate the effect of two tinted contact lenses (CL) designed for outdoor sports activity on the psychometric determination of retinal straylight using the compensation comparison method. METHODS: Thirteen emmetropic subjects were randomly fitted with two different tinted Nike Maxsight (Bausch & Lomb, Rochester, NY, USA) CL in one eye, while the contralateral eye was fitted with a clear lens mad...


Asphericity of the human cornea for different corneal diameters

González-Méijome, José Manuel; Villa-Collar, César; Montés-Micó, Robert; Gomes, Antonio

No author has a financial or proprietary interest in any material or method mentioned ; PURPOSE: To measure the anterior corneal asphericity (Q) with different corneal diameters. SETTING: Department of Physics (Optometry), University of Minho, Braga, Portugal. METHODS: Thirty-six eyes of 36 patients were evaluated using a videokeratoscope, and the Q-values were recorded. Topographic data were also analyzed usi...


Age differences in central and peripheral intra-ocular pressure using a rebound...

González-Méijome, José Manuel; Jorge, Jorge; Queirós, A.; Fernandes, Paulo Rodrigues; Montés-Micó, Robert; Almeida, José B.; Parafita, Manuel A.

To evaluate the influence of age on the measurements and relationships among central and peripheral IOP readings taken with a rebound tonometer. METHODS: The intraocular pressures were assessed using the ICare(R) rebound tonometer (Tiolat Oy, Helsinki, Finland) on the right eye of two-hundred and seventeen patients (88 males, 129 females), aged 18 to 85 years (meanSD, 45.919.8 years), at the center and at 2 mm ...