Encontrados 4 documentos, a visualizar página 1 de 1

Ordenado por Data

A computer-based testing system to evaluate protective relays as a tool in powe...

Martins, L. Sousa; Fortunato, Carlos; Pires, V. Fernão

Teaching power system relaying is a fundamental issue in a power system high-level course. However, for an effective instruction of this topic an experience with real equipments can be considered as fundamental. To achieve this purpose, in this paper a new approach for the practical learning of power system relaying is presented. This consists of a computer-based testing system of relay-operating characteristic...

Data: 2012   |   Origem: Repositório Comum

Transmission lines protection based on the current eigenvalues differential con...

Pires, V. Fernão; Guerreiro, M.; Fortunato, Carlos; Martins, L. Sousa

This work presents a new approach for a current differential protection of the transmission lines. The proposed approach is based on the Clarke-Concordia transformation and principal component analysis. First the acquired current signals are transformed into “αβo” components by applying the Clarke-Concordia transformation. This allows obtaining typical patterns. To identify these patterns a principal component ...

Data: 2010   |   Origem: Repositório Comum

A current differential line protection using a synchronous reference frame appr...

Martins, L. Sousa; Fortunato, Carlos; Pires, V. Fernão

This paper presents a new approach for a current differential protection of the transmission lines. This approach is based on the Park transformation or ABC-dqo transformation. Using the ABC-dqo transformation the three phase quantities are transformed into a synchronous rotating reference frame. In this way, the line currents of the three phase system are measured and transformed into three dc components. So, ...

Data: 2008   |   Origem: Repositório Comum

A power amplifier system for testing of distance relay operating characteristic

Marçal, Rui; Rodrigues, Ricardo; Fortunato, Carlos; Martins, L. Sousa; Pires, V. Fernão

This paper describes a power amplifier system for testing of distance relay operating characteristic. This power amplifier is based on two three phase inverters with a neutral wire. The output power currents and voltages are controlled by a sliding mode controller. A developed matlab/simulink digital simulator generates the test signals. This test signals are converted in current and voltage references using a ...

Data: 2006   |   Origem: Repositório Comum

4 Resultados

Texto Pesquisado

Refinar resultados

Autor







Data





Tipo de Documento



Recurso


Assunto















    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia