In vitro experiments allow precise measurement and control over relevant physiological variables. Thus, in the present study we have used a lithography technique to fabricate a rectangular PDMS microchannel with a bifurcation. By using a confocal micro-PTV system, we have measured the effect of bifurcation on the flow behaviour of both fluorescent particles diluted in pure water and red blood cells (RBCs) in co...
The blood flow dynamics in microcirculation depends strongly on the microvascular networks composed with short irregular vessel segments which are linked by numerous bifurcations. This paper presents the application of a confocal micro-PTV system to track RBCs through a rectangular polydimethysiloxane (PDMS) microchannel with a bifurcation. By using a confocal micro-PTV system, we have measured the effect of bi...
A dinâmica do escoamento sanguíneo na microcirculação depende fortemente das redes microvasculares compostas por segmentos de vasos curtos irregulares que estão ligados por inúmeras bifurcações. Este trabalho apresenta a aplicação de um sistema micro-PTV confocal para medir o comportamento dos eritrócitos durante o escoamento em um microcanal polidimetisiloxano (PDMS) rectangular com uma bifurcação. O efeito da...
Vários estudos revelaram que a informação obtida sobre as propriedades reológicas do sangue em capilares de vidro difere da situação in vivo (Pries et al. 1994). As principais causas potenciais para estas discrepâncias podem ser devidas à camada superficial formada por células endoteliais e às redes microvasculares compostas por segmentos de vasos irregulares e curtos que estão ligados por numerosas bifurcações...