A simple, economic, highly sensitive and highly selective method for the detection of caffeine has been developed at bare and Nafion-modified glassy carbon electrodes (GCE). The electrochemical behaviour of caffeine was examined in electrolyte solutions of phosphate buffer saline, sodium perchlorate, and in choline chloride plus oxalic acid, using analytical determinations by fixed potential amperometry, phosph...
A glassy carbon electrode modified with functionalized multi-walled carbon nanotubes (MWCNT), 1-butyl-3-methylimidazolium chloride (ionic liquid = IL) and tyrosinase (Tyr) within a dihexadecylphosphate (DHP) film for the development of a biosensor is proposed. MWCNT, IL and Tyr were efficiently immobilized in the film using 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide/N-hydroxysuccinimide (EDC/NHS) as crossli...
Functionalised graphene (G) and nitrogen doped graphene (NG) nanomaterials are excellent candidates for electrocatalytic sensing of biomolecules and for developing biosensors, due to their unique physicochemical and electronic properties. Electrochemical characterisation and comparison of basic or acidic functionalised G and NG has been carried out, as well as of composite materials based on NG with the conduct...
Gold-based screen-printed electrodes have been characterised by electrochemical impedance spectroscopy (EIS) to better understand their behaviour in electroanalytical applications, particularly in the anodic stripping voltammetry of Hg(II). After a first exploration by cyclic voltammetry, impedance spectra of gold-based screen-printed sensors were recorded in 0.1 M HCl electrolyte solution, in the presence of d...
Poly(3,4-ethylenedioxythiophene) (PEDOT) films have been prepared for the first time on carbon-film electrodes (CFE) in aqueous solution using electropolymerisation by potential cycling, potentiostatically and galavanostatically. Characterisation of the modified electrodes was done by cyclic voltammetry and electrochemical impedance spectroscopy and the stability of the polymer films was probed. The coated elec...
Biosensors have been prepared by modification of glassy carbon electrodes with functionalised multiwalled carbon nanotubes (MWCNT) dispersed in the room temperature ionic liquid, 1-butyl-3-methylimidazolium bis(trifluoromethane)sulfonimide (BmimNTF2) and with lipase cross-linked with glutaraldehyde. The biosensor was applied to the determination of olive oil triglycerides by cyclic voltammetry. A phosphate buff...
The effectiveness of immobilization of functionalized carbon nanotubes into chitosan using different cross-linking agents has been evaluated. The cross-linkers used were glyoxal (GO), glutaraldehyde (GA), epichlorohydrin (ECH), and 1-ethyl-3-(3-dimethylaminopropyl) carbodiimide together with N-hydroxysuccinimide (EDC-NHS), and the nanotubes were retained on graphite epoxy resin composite electrodes. The nanotub...
A new conducting composite flexible material prepared from cellulose acetate (CA) polymer and graphite has been developed and used for the fabrication of electrodes, which were then characterized by cyclic voltammetry and electrochemical impedance spectroscopy. Scanning electron microscopy (SEM) was used to provide information concerning the morphology of the composite electrode surface. The potential window, b...
Functionalised multi-walled carbon nanotubes (MWCNTs) were cast on glassy carbon (GC) and carbon film electrodes (CFE), and were characterised electrochemically and applied in a glucose-oxidase-based biosensor. MWCNT-modified carbon film electrodes were then used to develop an alcohol oxidase (AlcOx) biosensor, in which AlcOx-BSA was cross-linked with glutaraldehyde and attached by drop-coating. The experimenta...
Flow injection analysis (FIA) using a carbon film sensor for amperometric detection was explored for ambroxol analysis in pharmaceutical formulations. The specially designed flow cell designed in the lab generated sharp and reproducible current peaks, with a wide linear dynamic range from 5 × 10-7 to 3.5 × 10-4 mol L-1, in 0.1 mol L-1 sulfuric acid electrolyte, as well as high sensitivity, 0.110 A mol-1 L cm-2 ...
Financiadores do RCAAP | |||||||
![]() |
![]() |
![]() |
![]() |
![]() |
![]() |