Encontrados 8 documentos, a visualizar página 1 de 1

Ordenado por Data

Development and validation of an experimental life support system for assessing...

Coelho, Francisco J. R. C.; Rocha, Rui J. M.; Pires, Ana C. C.; Ladeiro, Bruno; Castanheira, José M.; Costa, Rodrigo; Almeida, Adelaide; Cunha, Ângela

An experimental life support system (ELSS) was constructed to study the interactive effects of multiple stressors on coastal and estuarine benthic communities, specifically perturbations driven by global climate change and anthropogenic environmental contamination. The ELSS allows researchers to control salinity, pH, temperature, ultraviolet radiation (UVR), tidal rhythms and exposure to selected contaminants. ...


6 MV wedge photon beam profiles with the fricke xylenol gel dosimeter

Oliveira,Lucas N. de; Calcina,Carmen Sandra Guzmán; Cavalcante,Fernanda; Almeida,Adelaide de; Almeida,Carlos Eduardo de

Wedged beam are often used in clinical radiotherapy to compensate missing tissues and dose gradients. In this work, the Fricke Xylenol Gel (FXG) dosimeter was used for 6 MV photons radiation wedge field profiles measurements, allowing to infer the wedge filter physical attenuation coefficient. This dosimeter is a chemical system of a Fe3+-Xylenol complex concentration, that when measured spectrophotometrically,...

Data: 2009   |   Origem: OASIS br

Qualidade microbiológica e química das águas de consumo humano do Distrito de B...

Nogueira, António José M.; Cardoso, Manuela; Delgadillo, Ivonne; Almeida, Adelaide

Foi avaliada a qualidade microbiológica e química da água de consumo humano do Distrito de Bragança e relacionada a variação do teor de microrganismos na água com as características químicas dessa água. A qualidade microbiológica das águas de consumo humano do Distrito de Bragança foi avaliada entre 1996 e 2005. A classificação das águas de consumo humano analisadas neste período baseou-se no Decreto-Lei n.º 74...

Data: 2009   |   Origem: Biblioteca Digital do IPB

Ferrous Xylenol Gel measurements for 6 and 10 MV photons in small field sizes

Oliveira,Lucas N. de; Guzmán Calcina,Carmen S.; Parada,Marco A.; Almeida,Carlos E. de; Almeida,Adelaide de

The Fricke dosimeter is a ferrous sulfate aqueous solution that, when irradiated, oxidizes the Fe2 + ions to Fe3 + . This new concentration, generally determined through spectrophotometry, is directly proportional to the ionizing radiation absorbed energy. The Fricke Xylenol Gel dosimeter (FXG) was developed through the incorporation of swine skin gelatin and xylenol orange. These modifications provided better ...

Data: 2007   |   Origem: OASIS br

Fluoropolymer studies for radiation dosymetry

Parada,Marco Aurélio; Minamisawa,Renato Amaral; Almeida,Adelaide de; Muntele,Claudiu; Zimmerman,Robert Lee; Muntele,Iulia; Ila,Daryush

The polymers Tetrafluoroethylene- hexa- fluoropropylene (FEP) and Tetrafluoroethylene- per- fluoromethoxyethelene (PFA) are normally used as anti-adherent coatings and can also be applied for several applications in research. For example, they can be used as radiation dosimeters for X-ray and gamma photons, electrons, protons and other ionazing particles. In order to determine radiation induced damage, that can...

Data: 2004   |   Origem: OASIS br

ANÁLISES DE PROTOCOLOS TELETERÁPICOS DE CONTROLE DE QUALIDADE DE ALGUNS SERVIÇO...

Calcina,Carmen S. Guzmán; Lima,Luciana P. de; Rubo,Rodrigo A.; Ferraz,Eduardo; Almeida,Adelaide de

Considerando a importância da garantia da qualidade nos serviços de radioterapia, este trabalho tem como primeiro objetivo fazer uma avaliação dos testes propostos pelos protocolos oficiais internacionais TG40 e ARCAL XXX para os equipamentos de cobalto, acelerador linear e simulador. O segundo objetivo consistiu em se fazer uma avaliação dos testes que atualmente são realizados por alguns serviços de radiotera...

Data: 2002   |   Origem: OASIS br

Análises de protocolos de braquiterapia, por alta taxa de dose, do controle de ...

Calcina,Carmen S. Guzmán; Almeida,Adelaide de; Rocha,José R.Oliveira

A braquiterapia por alta taxa de dose está recebendo atenção considerável na maioria dos países. Por isso, nos serviços que utilizam este equipamento exige-se que o desenvolvimento de um programa de controle de qualidade seja cada vez mais rigoroso, para garantir não apenas a segurança aos pacientes, mas também aos operadores e demais envolvidos. Este trabalho tem por objetivos fazer um levantamento dos tipos d...

Data: 2001   |   Origem: OASIS br

Crescimento e mortalidade do bacterioplâncton em ambiente estuarino (Ria de Ave...

Almeida, Adelaide de

O objectivo deste trabalho foi estudar o fluxo de materiais e de energia no bacteriopâncton do complexo sistema da Ria de Aveiro. O estudo de campo permitiu caracterizar perfis longitudinais, verticais e tidais de abundância e de produtividade bacteriana, pondo em evidência alguns dos factores que controlam esses padrões de variação. Os ensaios laboratoriais foram realizados para caracterizar o potencial bacter...


8 Resultados

Texto Pesquisado

Refinar resultados

Autor











Data







Tipo de Documento




Recurso





Assunto















    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia