Document details

Tumour ADC measurements in rectal cancer: effect of ROI methods on ADC values a...

Author(s): Lambregts, DM cv logo 1 ; Beets, GL cv logo 2 ; Maas, M cv logo 3 ; Curvo-Semedo, L cv logo 4 ; Kessels, AG cv logo 5 ; Thywissen, T cv logo 6 ; Beets-Tan, RG cv logo 7

Date: 2011

Persistent ID: http://hdl.handle.net/10400.4/1311

Origin: Repositório do Centro Hospitalar e Universitário de Coimbra

Subject(s): Neoplasias do Recto


Description
OBJECTIVES: To assess the influence of region of interest (ROI) size and positioning on tumour ADC measurements and interobserver variability in patients with locally advanced rectal cancer (LARC). METHODS: Forty-six LARC patients were retrospectively included. Patients underwent MRI including DWI (b0,500,1000) before and 6-8 weeks after chemoradiation (CRT). Two readers measured mean tumour ADCs (pre- and post-CRT) according to three ROI protocols: whole-volume, single-slice or small solid samples. The three protocols were compared for differences in ADC, SD and interobserver variability (measured as the intraclass correlation coefficient; ICC). RESULTS: ICC for the whole-volume ROIs was excellent (0.91) pre-CRT versus good (0.66) post-CRT. ICCs were 0.53 and 0.42 for the single-slice ROIs versus 0.60 and 0.65 for the sample ROIs. Pre-CRT ADCs for the sample ROIs were significantly lower than for the whole-volume or single-slice ROIs. Post-CRT there were no significant differences between the whole-volume ROIs and the single-slice or sample ROIs, respectively. The SDs for the whole-volume and single-slice ROIs were significantly larger than for the sample ROIs. CONCLUSIONS: ROI size and positioning have a considerable influence on tumour ADC values and interobserver variability. Interobserver variability is worse after CRT. ADCs obtained from the whole tumour volume provide the most reproducible results. Key Points • ROI size and positioning influence tumour ADC measurements in rectal cancer • ROI size and positioning influence interobserver variability of tumour ADC measurements • ADC measurements of the whole tumour volume provide the most reproducible results • Tumour ADC measurements are more reproducible before, rather than after, chemoradiation treatment • Variations caused by ROI size and positioning should be taken into account when using ADC as a biomarker for tumour response.
Document Type Article
Language English
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Related documents



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento EU