Document details

Finite element analysis of the ECT test on mode III interlaminar fracture of ca...

Author(s): Moura, M. F. S. F. de cv logo 1 ; Silva, M. A. L. cv logo 2 ; Morais, A. B. de cv logo 3 ; Morais, J. J. L. cv logo 4

Date: 2006

Persistent ID: http://hdl.handle.net/10773/5474

Origin: RIA - Repositório Institucional da Universidade de Aveiro


Description
In this work a parametric study of the Edge Crack Torsion (ECT) specimen was performed in order to maximize the mode III component (GIII) of the strain energy release rate for carbon-epoxy laminates. A three-dimensional finite element analysis of the ECT test was conducted considering a [90/0/(+45/-45)2/(-45/+45)2/0/90]S lay-up. The main objective was to define an adequate geometry to obtain an almost pure mode III at crack front. The geometrical parameters studied were specimen dimensions, distance between pins and size of the initial crack. The numerical results demonstrated that the ratio between the specimen length and the initial crack length had a significant effect on the strain energy release rate distributions. In almost all of the tested configurations, a mode II component occurred near the edges but it did not interfere significantly with the dominant mode III state. FCT - POCTI/EME/45573/2002
Document Type Conference Object
Language English