Corneal transparency after cross-linking for keratoconus : 1-year follow-up

Autor(es): Gutiérrez, Ángel Ramón cv logo 1 ; Lopez, Inma cv logo 2 ; Villa-Collar, César cv logo 3 ; González-Méijome, José Manuel cv logo 4

Data: 2012

Identificador Persistente: http://hdl.handle.net/1822/27041

Origem: RepositóriUM - Universidade do Minho


Descrição
PURPOSE: To evaluate the changes in corneal transparency and thickness measured objectively using Pentacam Scheimpfl ug (Oculus Optikgerate GmbH) corneal tomography (densitometry) after corneal cross-linking (CXL). METHODS: Twenty-two eyes from 15 patients with keratoconus underwent CXL. Corneal thickness and curvature as well as lens and corneal densitometry were measured at baseline and 1, 3, 6, and 12 months after CXL with Pentacam. RESULTS: Immediately after CXL, central corneal thickness signifi cantly decreased (240 ƒÊm) and corneal densitometry increased signifi cantly. At 6-month followup, densitometry values were reduced and seemed to stabilize at a higher value than baseline. No statistically signifi cant differences were noted (mean difference at 12 months: 130%). Changes in corneal densitometry were detected with the Pentacam even when clinical haze did not increase beyond grade 1 during follow-up. CONCLUSIONS: Corneal CXL is associated with a transient reduction in central corneal thickness, which recovered to baseline after 12 months. During the same time period, corneal densitometry experienced a transient increase that recovered to baseline values after 3 months. Changes in compactness of the corneal tissue after CXL may have an impact in corneal power not due to curvature changes, but to refractive index changes as a result of hydration changes. Pentacam is a useful objective method to monitor corneal transparency after CXL.
Tipo de Documento Artigo
Idioma Inglês
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Documentos Relacionados



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia