Detalhes do Documento

Dynamic identification and monitoring of St. Torcato Church

Autor(es): Ramos, Luís F. cv logo 1 ; Alaboz, Murat cv logo 2 ; Aguilar, Rafael cv logo 3

Data: 2010

Identificador Persistente: http://hdl.handle.net/1822/18796

Origem: RepositóriUM - Universidade do Minho

Assunto(s): Dynamic identification; Modal updating; Dynamic monitoring


Descrição
The paper is related to the San Torcato Church, in Guimarães, Portugal. At the moment, the church has significant structural problems due to soil settlements. Cracks can be observed on the main and the lateral façades, the bell-towers are leaning, and the arches in the nave exhibit a failure mechanism with cracks and vertical deformations. Non-stabilized phenomena are present in the structure. To stabilize the damage, a structural intervention is planned to occur soon and the church is already monitored to follow the intervention. The paper clearly presents the problem with emphasis to the dynamic analysis carried out before the structural strengthening, namely: the experimental tests with output-only techniques for frequencies, damping and mode shapes estimation, FE model updating analysis and dynamic monitoring
Tipo de Documento Documento de conferência
Idioma Inglês