Document details

Seismic assessment of masonry “Gaioleiros” buildings in Lisbon, Portugal

Author(s): Mendes, N. cv logo 1 ; Lourenço, Paulo B. cv logo 2

Date: 2010

Persistent ID: http://hdl.handle.net/1822/17286

Origin: RepositóriUM - Universidade do Minho

Subject(s): "Gaioleiro” buildings; Masonry; Earthquake; Seismic assessment; Non-linear time history analysis; Pushover analysis


Description
This paper presents a numerical study for the seismic assessment of a Portuguese building masonry typology - “Gaioleiro”. Numerical analysis was performed using a finite element model calibrated with experimental results obtained in 1:3 reduced scale tests carried out in the LNEC 3D shaking table. Non-linear dynamic analysis with time integration and pushover analysis are carried out. Using nonlinear dynamic analysis it was verified that the buildings of “gaioleiro” type with appropriate floor-wall connections are in the limit of their loading capacity. The pushover analyses performed in this study were incapable of simulating correctly the damage of the structure under seismic action.
Document Type Article
Language English
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Related documents

No related documents


    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento EU