Detalhes do Documento

Bond characterization between concrete base and repairing SFRC by pull-off tests

Autor(es): Bonaldo, Everaldo cv logo 1 ; Barros, Joaquim A. O. cv logo 2 ; Lourenço, Paulo B. cv logo 3

Data: 2004

Identificador Persistente: http://hdl.handle.net/1822/12999

Origem: RepositóriUM - Universidade do Minho

Assunto(s): Pull-off test; Epoxy adhesive; Thin-bonded overlay; Steel fibre reinforced


Descrição
Technical report 04-DEC/E-13 In the last years an emerging repair and strengthening technique for concrete slabs has been used, consisting of applying a thin layer of steel fibre reinforced concrete (SFRC) onto the existent concrete slab. The performance of the structural system depends on the bonding behaviour between old and new concretes. Adhesives based on epoxy resins currently make this liaison. The prices of these adhesives are quite different depending, mainly, on the percentage of pure resin that they include. In the present report, three commercial adhesive compounds of distinct prices and properties were selected to bond concrete base and repairing SFRC. The bond behaviour was assessed from pull-off tests and the influence of the strength class of concrete base and repairing SFRC was analysed. Finally, the performance of the adhesives was evaluated, considering both the bond strength and their prices.
Tipo de Documento Relatório