Detalhes do Documento

The use of attached-sunspaces in retrofitting design: the case of residential b...

Autor(es): Aelenei, Daniel cv logo 1 ; Leal, Hugo de Azevedo cv logo 2 ; Aelenei, Laura cv logo 3

Data: 2014

Identificador Persistente: http://hdl.handle.net/10400.9/2480

Origem: Repositório do LNEG

Assunto(s): Attached-sunspace; Retrofitting; Residential Buildings; Thermal Performance; Simulation


Descrição
This study addresses the energetic performance of an attached-sunspace applied to an existing residential building in Portugal. Four configurations (two attached, one integrated and one partially integrated) are studied in six different climatic zones. In addition other key parameters are considered such as ventilation (with or without natural ventilation), shading devices (one external and two internal configurations), number of glazed surface layers (single glazed and double glazed) and orientation (South, East and West). The thermal performance analysis, carried out using a dynamic simulation code, proved that energy savings for retrofitting design can be very important and that in climates with warm summers the risk of overheating can be considerably diminished through an accurate analysis based on modeling.
Tipo de Documento Artigo
Idioma Inglês
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Documentos Relacionados



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia