Document details

Damage assessment of drilled hybrid composite laminates

Author(s): Durão, Luís M. cv logo 1 ; Magalhães, A. G. cv logo 2 ; Marques, A. T. cv logo 3 ; Tavares, João Manuel R. S. cv logo 4

Date: 2008

Persistent ID: http://hdl.handle.net/10400.22/4244

Origin: Repositório Científico do Instituto Politécnico do Porto


Description
Hole drilling operations are common in fibre reinforced plastics - FRP’s - to facilitate fastener assembly to other parts in more complex structures. As these materials are non-homogeneous, drilling causes some damages, like delamination, for example. Delamination can be reduced by a careful selection of drilling parameters, drill material and drill bit geometry. In this work two types of laminates are drilled using different machining parameters and comparing drill geometries. Results show the importance of a cautious selection of these variables when composites’ drilling is involved.
Document Type Article
Language English
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Related documents



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento EU