Detalhes do Documento

Avalanche-ion back-flow reduction in gaseous electron multipliers based on GEM/...

Autor(es): Maia, J. M. cv logo 1 ; Mörmann, D. cv logo 2 ; Breskin, A. cv logo 3 ; Chechik, R. cv logo 4 ; Veloso, J. F. C. A. cv logo 5 ; Santos, J. M. F. dos cv logo 6

Data: 2004

Identificador Persistente: http://hdl.handle.net/10316/4448

Origem: Estudo Geral - Universidade de Coimbra

Assunto(s): Gas avalanche electron multipliers; Gaseous photomultipliers; Ion back-flow


Descrição
We report on avalanche-ion back-flow measurements in the novel Micro-Hole and Strip-Plate (MHSP) multiplier and in gaseous photomultipliers comprising Gas Electron Multipliers (GEMs) followed by an MHSP. In a 3-GEMs/MHSP photomultiplier with reflective photocathode, avalanche-ion back-flow fraction of ~7% and ~2% were recorded for respective effective gains of 107 and 106, in Ar/CH4 (95/5) at 760 Torr. This is about one order of magnitude reduction in ion back-flow compared to the best values measured in 4-GEMs photomultiplier at the same gain. We describe the mode of operation of the MHSP and explain its ion back-flow reduction features. http://www.sciencedirect.com/science/article/B6TJM-4BMBDH7-C/1/cdedfd1e72d3adbcfc9431895ab3e612
Tipo de Documento Artigo
Idioma Inglês
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Documentos Relacionados



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia