Ceramic high-rate timing RPCs

Autor(es): Lopes, L. cv logo 1 ; Marques, R. Ferreira cv logo 2 ; Fonte, P. cv logo 3 ; Hennetier, L. cv logo 4 ; Pereira, A. cv logo 5 ; Correia, A. M. Sousa cv logo 6

Data: 2006

Identificador Persistente: http://hdl.handle.net/10316/4397

Origem: Estudo Geral - Universidade de Coimbra

Assunto(s): High-rate; Ceramic electrode


Descrição
Following some previous work, we report here considerable improvements on the counting rate capability of timing RPCs by the use of ceramic electrodes with a resistivity of 109 [Omega][dot operator]cm. The X-ray sensitivity of the detector depends linearly on the counting rate with a slope of 9% per 100 kHz/cm2, free from charge depletion effects, while keeping a timing accuracy, measured with 511 keV synchronous photon pairs, around 90 ps [sigma] up to 75 kHz/cm2. http://www.sciencedirect.com/science/article/B6TVD-4KV4MR8-K/1/ea4432be2a0e736afc8220e837ad51bb
Tipo de Documento Artigo
Idioma Inglês