Document details

Improvement of the mechanical response of an electrical component

Author(s): Antunes, F. J. V. cv logo 1 ; Costa, J. D. M. cv logo 2 ; Ferreira, J. A. M. cv logo 3

Date: 2003

Persistent ID: http://hdl.handle.net/10316/4266

Origin: Estudo Geral - Universidade de Coimbra

Subject(s): Plastic deformation; Geometry optimisation; Finite element analysis; Electrical-component failures; Friction


Description
The electrical component under analysis does not fulfil the mechanical performance required by the standard (a minimum force of 400 gf during the extraction of a 3.8 mm diameter pin after the introduction of a 5.1 mm pin). A numerical study using the finite element method was developed to understand the limited response of the component and to study the effect of changing material and geometry. Experimental tests were performed to obtain the elastic-plastic behaviour of the material and friction coefficient. The poor performance was explained by the exaggerated plastic deformation. The best solution was found to be the use of a new material (extra-hard brass) since the geometrical changes allowed have a limited effect. http://www.sciencedirect.com/science/article/B6V2X-48WB5MF-2/1/2f85edb5e94da04923e5e57e4d0ff031
Document Type Article
Language English