Detalhes do Documento

Damage localization in laminated composite plates using double pulse-electronic...

Autor(es): Santos, J.V. Araújo dos cv logo 1 ; Lopes, H. cv logo 2 ; Vaz, M.A.P. cv logo 3 ; Soares, C.M. Mota cv logo 4 ; Soares, C.A. Mota cv logo 5 ; Freitas, M.J.M. de cv logo 6

Data: 2006

Identificador Persistente: http://hdl.handle.net/10198/4229

Origem: Biblioteca Digital do IPB

Assunto(s): Damage localization; Laminated plate; Mode shape curvature; Pulse- electronic holographic interferometry; Acoustic excitation; Non destructive inspection.


Descrição
One method for the damage localization of impact damage in laminated composite plates, based on their vibrational characteristics, is presented in this paper. This method uses double pulse-electronic holographic interferometry for mode shapes acquisition and the differences in curvatures. The rotations and curvatures are numerically obtained. The method is applied to a carbon fibre reinforced epoxy rectangular plate, free in space, subjected to two cases of impact damage. It is shown that the method based on curvatures allows for the localization of both cases of damage, which can be undetected by visual, X-ray or C-Scan inspections. The best localizations are achieved by selecting and applying the method to the most changed mode.
Tipo de Documento Documento de conferência
Idioma Inglês
delicious logo  facebook logo  linkedin logo  twitter logo 
degois logo
mendeley logo

Documentos Relacionados



    Financiadores do RCAAP

Fundação para a Ciência e a Tecnologia Universidade do Minho   Governo Português Ministério da Educação e Ciência Programa Operacional da Sociedade do Conhecimento União Europeia